Insulation Laminated Wood

Insulation Laminated Wood

Normal Thickness:8
Tolerance:±1.4
Send Inquiry
Chat Now
Description
Products Description

 

Insulation Laminated Wood is a high-strength insulating material developed specifically for the electrical industry. It consists of multiple layers of high-quality birch wood, impregnated with epoxy or phenolic resins and laminated under high temperature and pressure. This material combines mechanical strength with insulating properties and is widely used in power equipment such as transformers and motors.

 

Procurement Parameter Confirmation Checklist (for customer reference):
1/Application: Dry-type/oil-immersed transformer? Motor? High-voltage switchgear?
2/Insulation class requirement: A/B/F?
3/Is special shaping required?
4/Load-bearing structure or just a gasket?
5/Working environment humidity and temperature?
6/Purchase quantity (m³/unit/ton)?
7/Is a test report required? (e.g., CTI, insulation resistance, flexural strength)

 

Product advantages:

 

1. Good insulation performance:
Insulation laminated wood e has high resistivity and dielectric strength and is not prone to static electricity. It is an excellent insulating material and is suitable for the manufacturing of electrical and electronic products.

2. Good heat resistance: Insulation laminated wood has a high thermal deformation temperature and thermal stability, can be used in high-temperature environments, and is not easy to deform or burn.

3. Good corrosion resistance:

Insulation laminated wood has good water resistance, acid resistance, alkali resistance, and oil resistance. It can be used in various chemical media and is not easily corroded or aged.

4. High mechanical strength:

Insulation laminated wood has high compressive strength, bending strength, and impact resistance, can withstand large mechanical loads, and is not easy to break or shatter.

5. Strong plasticity: Insulation laminated wood has good plasticity and processability. It can be pressed into products of various shapes and sizes through molds, and can also be secondary processed through cutting, drilling, grinding, etc. Product advantages:

 

Boards Flatness(Unit mm)
Normal Thickness Distance of points on the veneer face from light weight straight ruler
500 straight ruler 11000straight ruler
≤15 2 4
>15...≤25 1.5 3
>25...<60 1 2
>60 1 1
Normal Length and Width Tolerance (Unit mm)
Length and Width Tolerance
>100...≤250 ±0.8
>250...≤500 ±1.0
>500...≤1000 ±2.0
>1000...≤2000 ±3.0
>2000 ±4.0
Product Display

 

Laminated veneer lumber for transformer
Electric laminate wood.
product-750-750
Electric laminate wood high quality

 

Surface Quality

 

Item Allowed Range
Swelling Not Allowed
Cracking
Dead Knot
Foreign-body Adhering
Insect Hole
Rot
Contamination
Bruising A few allowed, not effect in usage
Impression
Color-odds and Splash
Patches per sq.m.on surface ≤3

 

Normal Thickness and Tolerance (Unit mm)

 

Normal Thickness Tolerance
≤10 ±1.4
>10...≤15 ±1.6
>15...≤20 ±1.8
>20...≤25 ±2.0
>25...≤30 ±2.2
>30...≤40 ±2.6
>40...≤60 ±3.0
>60...≤100 ±4.0
>100...≤150 ±4.0
Products Specification (Unit mm)

Veneer Maximum Specification:4000x3000x120

Veneer Maximum Specification: (length x width x thickness)

Veneer Usual Specification:

3000x1500x(10-120)

2400x2000x(10-120)

Veneer Usual Specification:

(length x width x thickness)

X-Shape Pressure Ring Maximum Diameter:3000

 

Packing

 

Insulation Laminated Wood Packaged in wooden crates, wooden framed cases or other strong enough materials covered with moisture-proof materialoutside.

Gross weight of each package not exceeds 3000kgs.

1
3
2
5

 

Storage

 

Products should be stored in a clean and dry room with temperature not exceeding 40℃ and should be laid flat wise on a stepping-board which is at least 50mm from the ground, never close to fre source, heat source and protected against moisture.

 

Application scenarios

 

TYPICAL APPLICATIONS IN ELECTRIC MOTORS:

1Trough Insulation

2InterlayerInsulation

3Phase Insulation

4Slot Wedge Insulation

 

Typical applications in transformers:

1Winding layer insulation

2Turn-to-turn insulation

3Screen insulation

4End insulation

 

1
2
3

 

About us

1,Wide range of product category

All necessary material for liquid/cast resin transformer, Motors. The thermal class covers: A, B, F, H, N.

2,Direct Trading of Various Electrical Products

All Electrical insulation material are approved by High Voltage and Low Voltage Transformer Bushing, Tap Changer, Transformer Core, DDP Paper, DDP Film, DMD prepreg materials.

3,Product quality excellence

Passed ISO9001 quality system certification and obtained a national invention patent.

 

Production process
product-285-188
Birch
product-285-188
Gluing
product-285-188
Arranging
product-285-188
Hot-pressing
product-285-188
Finished products
Factory Display
1-210ZQ64435954
Splice press
1-210ZQ64051J8
Machining centers
1-210ZQ6420RM
Low temperature dryer
1-210ZZ03000554
workshop
OIP-C 2
produce
OIP-C
team

 

FAQ

 

01/

Q: I don't see my designed dimensions/ packaging/ delivery etc. Can you make a special order for us?

A: Sure. We're truly customized. You're free to tell us whatever you want.

02/

Q: Do you deal with urgent orders?

A: Sure. Please contact ASAP for details.

03/

Q: I bought from you once. Can I have a special offer this time?

A: Contact for details. We do value our customers; we can and will offer you good price.

Hot Tags: insulation laminated wood, China insulation laminated wood suppliers, printed circuit board laminates, laminated tolerances, laminated finishing, melamine laminates, laminated manufacturer directory, rigid laminate competition