Indoor Backup Fuse

Indoor Backup Fuse

Products Description Product name:Indoor backup fuse Minimum order quantity: 50 pieces Samples: Free of charge, but freight needs to be borne by customers Price: EXW/FOB Payment: T/T An indoor backup fuse is a protective component installed in indoor high-voltage or medium-voltage electrical...
Send Inquiry
Chat Now
Description

Products Description

Product name:Indoor backup fuse
Minimum order quantity: 50 pieces
Samples: Free of charge, but freight needs to be borne by customers
Price: EXW/FOB
Payment: T/T

Product Name Product Model Rated Voltage (kV) Current Rating (A) A (mm) B (mm) ⌀d (mm)
Backup Fuse XRNG1 - 15.5/10 - 50 15 10 368 324 53
Backup Fuse XRNG1 - 15.5/16 - 50 15 16 368 324 53
Backup Fuse XRNG1 - 15.5/20 - 50 15 20 368 324 53
Backup Fuse XRNG1 - 15.5/25 - 50 15 25 368 324 53
Backup Fuse XRNG1 - 15.5/31.5 - 50 15 31.5 368 324 53
Backup Fuse XRNG1 - 15.5/40 - 50 15 40 368 324 53
Backup Fuse XRNG1 - 15.5/50 - 50 15 50 368 324 53
Backup Fuse XRNG1 - 15.5/65 - 50 15 65 368 324 53
Backup Fuse XRNG1 - 15.5/80 - 50 15 80 368 324 53
Backup Fuse XRNG1 - 15.5/110 - 50 15 100 368 324 53
Backup Fuse XRNG1 - 15.5/125 - 50 15 125 368 324 53
Backup Fuse XRNG1 - 15.5/150 - 50 15 150 405 373 76
Backup Fuse XRNG1 - 15.5/160 - 50 15 160 405 373 76
Backup Fuse XRNG1 - 15.5/175 - 50 15 175 405 373 76
Backup Fuse XRNG1 - 40.5/10 - 31.5 40.5 10 570 537 53
Backup Fuse XRNG1 - 40.5/16 - 31.5 40.5 16 570 537 53
Backup Fuse XRNG1 - 40.5/20 - 31.5 40.5 20 570 537 53
Backup Fuse XRNG1 - 40.5/25 - 31.5 40.5 25 570 537 53
Backup Fuse XRNG1 - 40.5/31.5 - 31.5 40.5 31.5 570 537 53
Backup Fuse XRNG1 - 40.5/40 - 31.5 40.5 40 570 537 53
Backup Fuse XRNG1 - 40.5/50 - 31.5 40.5 50 570 537 53

 

An indoor backup fuse is a protective component installed in indoor high-voltage or medium-voltage electrical equipment. Its main function is to quickly cut off the fault current when a short circuit or severe overload occurs in the power system, protecting key equipment such as main switches, circuit breakers, and transformers from being burned.

Structural composition:
1.Fuse Element: Inductive current, melts when it exceeds the rated value
2.Fuse Tube: Shell, mostly high-strength porcelain or epoxy glass fiber
3.Connector end cap: Connected to the equipment circuit
4.Arc-extinguishing material: such as quartz sand, to prevent arc from spreading when melting


Why choose us?
- Support OEM/ODM, adapt to ABB, Siemens, Schneider and other cabinets
- Fast delivery, sufficient inventory, regular models can be shipped on the same day
- Provide one-stop solution for heat shrink/cold shrink installation accessories
- international standard: IEC, GB, DIN, etc.
- Provide technical guidance for selection and on-site installation assistance

 

What is the difference from a current limiting fuse?

 

Type Backup Fuse Current - Limiting Fuse
Functional Focus Mainly interrupts high - current short circuits to protect main equipment Quickly limits the peak value of fault current and reduces impact energy
Can It Protect Low - current Faults Alone? No Yes (Can act earlier)
General Matching Used with load switches Used with current - limiting circuit breakers

Hot Tags: indoor backup fuse, China indoor backup fuse suppliers